Product: XO (Clock Oscillator)
Series: SWO, H53, H32
Oscillator Type: Clock Oscillators - 125 MHz and under
Series: SWO, H53, H32
Oscillator Type: Clock Oscillators - 125 MHz and under
• Frequency in Hz and KHz range.
• Current consumption µA range.
LPO (Low Power Oscillator), such as 32.768 KHz, provides time base for real-time clocks.
Its low current consumption (only 6.5 µA for model 37LPO) makes it ideal for
battery-operated devices such as data loggers and portable test equipment.
| Package Code | Frequency Range | Assembly Technique | Package Size (mm) [inches] / Seat Height |
| Thru-Hole Types | |||
H14
|
20 KHz ~ 160 MHz | 4 pin DIL full size |
12.8mm x 20.2mm x 5.88mm 0.504in. x 0.795in. x 0.231in. |
|---|---|---|---|
H8
|
20 KHz ~ 160 MHz | 4 pin DIL half size |
12.8 x 12.8 x 5.88 0.504in. x 0.504in. x 0.231in. |
| Surface Mount Types - Gull Wing | |||
H24 |
20 KHz ~ 160 MHz | Gull wing version of H14 |
12.8mm x 20.2 x 7.60mm 0.504in. x 0.795in. x 0.300in. |
H18
|
20 KHz ~ 160 MHz | Gull wing version of H8 |
12.8mm x 12.8mm x 7.60mm 0.504in. x 0.504in. x 0.300in. |
| Surface Mount Types - Leadless | |||
|
H41 |
20 KHz ~ 160 MHz | 4 pad Leadless |
9.6mm x 11.4mm x 1.85mm 0.378in. x 0.449in. x 0.073in. |
H42
|
20 KHz ~ 160 MHz | 4 pad Leadless |
9.6mm x 11.4mm x 2.5mm 0.378in. x 0.449in. x 0.098in. |
H44
|
20 KHz ~ 160 MHz | 4 pad Leadless |
9.6mm x 11.4mm x 4.7mm 0.378in. x 0.449in. x 0.185in. |
H575
|
20 KHz ~ 160 MHz | 6 pad Leadless |
5.0mm x 7.5mm x 2.8mm 0.197in. x 0.295in. x 0.110in. |
SWO11
|
20 KHz ~ 160 MHz | 4 pad Ceramic Leadless |
5mm x 7mm x 1.1mm 0.197in. x 0.276in. x 0.043in. |
SWO
|
20 KHz ~ 160 MHz | 4 pad Ceramic Leadless |
5mm x 7mm x 1.4mm 0.197in. x 0.276in. x 0.055in. |
"LPO" Series General Specifications:
Fosc=32.768 KHz, TA= +25°C, VDD= 5.0V, Load: 10MΩ // 10 pF
Fosc=32.768 KHz, TA= +25°C, VDD= 5.0V, Load: 10MΩ // 10 pF
| Model | " SWO " ; " H53 " and " H32 " series | |||
|---|---|---|---|---|
| Overall Frequency Range | Supply Voltage Choices | Output Logic | Package Dimensions | |
| " SWO " series | 0.3125 ~ 125 MHz | 1.8 V, 2.5 V, 3.3 V, or 5.0 V | HCMOS | 5.0 x 7.0 x 1.4 mm |
| " H53 " series | 2.5 ~ 66 MHz | 1.8 V, 2.5 V, or 3.3 V | HCMOS | 3.2 x 5.0 x 1.2 mm |
| " H32 " series | 1.0 ~ 54 MHz | 1.8 V, 2.5 V, or 3.3 V | HCMOS | 2.5 x 3.2 x 1.0 mm |
| Input Voltage (VDD) | +1.8V D.C. ±5% | +2.5V D.C. ±5% |
|
+5.0V D.C. ±5% |
| Frequency Range | 1.0 ~ 60.0 MHz | 0.3 ~ 80.0 MHz | 0.3 ~ 125.0 MHz | 0.5 ~ 125.0 MHz |
| Output Logic High "1" (90% of VDD min.) | 1.62 V min. | 2.25 V min. | 2.97 V min. | 4.5 V min. |
| Output Logic Low "0" (10% of VDD max.) | 0.18 V max. | 0.25 V max. | 0.33 V max. | 0.5 V max. |
| Current Consumption | 1.0 ~ 1.5 MHz : 5mA | 0.3 ~ 1.5 MHz : 5mA | 0.3 ~ 1.5 MHz : 5mA | 0.3 ~ 1.5 MHz : 5mA |
| 1.5 ~ 20 MHz : 8mA | 1.5 ~ 20 MHz : 8mA | 1.5 ~ 20 MHz : 8mA | 1.5 ~ 20 MHz : 10mA | |
| 20 ~ 50 MHz : 15mA | 20 ~ 50 MHz : 15mA | 20 ~ 50 MHz : 15mA | 20 ~ 50 MHz : 25mA | |
| 50 ~ 60 MHz : 22mA | 50 ~ 125 MHz : 25mA | 50 ~ 125 MHz : 35mA | 50 ~ 125 MHz : 40mA | |
| Frequency Stability (1) Commercial (-10°C to +70°C) |
Stability Code "A": ±25 ppm Stability Code "B": ±50 ppm Stability Code "C": ±100 ppm If non-standard please enter the desired ppm stability after the "C" (e.g. C20 represents ±20 ppm) |
|||
| Frequency Stability(1) Industrial (-40°C to +85°C) |
Stability Code "D": ±25 ppm Stability Code "E": ±50 ppm Stability Code "F": ±100 ppm If non-standard please enter the desired ppm stability after the "I" (e.g. I20 represents ±20 ppm) |
|||
| Load | 15 pF max. ; (30 pF and 50 pF load are also available for +3.3V and +5.0V VDD) | |||
| Duty Cycle | Standard: 50% ± 10% ; Optional (add "-S" after part number): 50% ± 5% | |||
| Start-up Time (TS) | 1.0 ~ 32.0 MHz : 5 ms (max.) ; 32.0 ~ 125.0 MHz : 10 ms. (max.) | |||
| Rise Time (Tr) and Fall Time (Tf) | 5 ns (max.) | 7 ns (max.) | 10 ns (max.) | 10 ns (max.) |
| Measured between 10% ↔ 90% of wave form (CL = 15 pF) | ||||
| Storage Temperature | -50°C to 100°C | |||
| Aging | ± 5 ppm per year (max.) | |||
| Tri-state Function on Pad No. 1 | Note: Pad no. 1 is Tri-state by default for SWO, H53 and H32 series. Tri-state enable high. No connection or 90% of VDD min is applied to Tri-State pad to enable output. 10% of VDD max. to disable output. |
|||
(1)Inclusive of 25°C tolerance, operating temperature range, ±10% input voltage variation, load change, aging, shock and vibration.