Product: XO (Clock Oscillator)
Series: HPL
Output: PECL Logic Output

Selection Guide - Specifications

• HPL Series (PLL-based): Low cost.
• Moderate phase noise and jitter.
• -125 dBc/Hz at 10 KHz offset (155.520 MHz)
• Differential PECL Outputs.
• Covers applications from ADSL to SONET.

HPL Series Data Sheets: (by package and supply voltages)

Package Photo Product Series
Supply
Voltage
Freq. min.(MHz) Freq. max.(MHz) No. of pins or pads Package Size (mm) / Description  / Features
3HPL5761 3.3 V 0.75 800 6 5x72.5, Tri-state on pad 1. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL5762 3.3 V 0.75 800 6 5x72.5, Tri-state on pad 2. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL14 3.3 V 0.75 800 4 Full Size 4  pin DIP. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL24 3.3 V 0.75 800 4 Full Size 4  pin Gull Wing SMD. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL8 3.3 V 0.75 800 4 Half Size 4  pin DIP. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL18 3.3 V 0.75 800 4 Half Size 4  pin Gull Wing SMD. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL62 3.3 V 0.75 800 6 9.6x11.4x2.5 mm 6 pad FR4 SMD. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
3HPL64 3.3 V 0.75 800 6 9.6x11.4x4.7 mm 6 pad FR4 SMD. PLL based, 6 pad SMD. Low cost. Moderate phase noise.  -125 dBc/Hz at 10 KHz offset for 155.520 MHz.
General Specifications:
  TA=+25°C, VDD= at specified voltage, Load: 10 KΩ // 10 pF


Mercury Model HPL
Frequency Range
(package dependent)
750 KHz ~ 800 MHz. PLL-based.
Output Logic Differential PECL 100K Square Wave

Frequency Stability (1)

Commercial (0°C to +70°C)
Temperature Code is "C"



Industrial (-40°C to +85°C)
Temperature Code is "I"
Stability Code "A": ±25 ppm over 0°C to +70°C
Stability Code "B": ±50 ppm over 0°C to +70°C
Stability Code "C": ±100 ppm over 0°C to +70°C
If non-standard please enter the desired stability after the "C"
(e.g. C20 represents ±20 ppm over 0°C to +70°C)
Stability Code "D": ±25 ppm over -40°C to +85°C
Stability Code "E": ±50 ppm over -40°C to +85°C
Stability Code "F": ±100 ppm over -40°C to +85°C
If non-standard please enter the desired stability after the "I"
(e.g. I20 represents ±20 ppm over -40°C to +85°C)
vs ±10% Supply Voltage Change: ±3 ppm max.
vs ±10% Load Change: ±2 ppm max.
Supply Voltage (VDD) 3.3 V ± 10%
Output Voltage HIGH "1" VOH VDD-1.025 V min.; VDD-0.880 V max. Condition: RL= 50 Ω to VDD-2V
Output Voltage LOW "0" VOL VDD-1.810 V min.; VDD-1.620 V max. Condition: RL= 50 Ω to VDD-2V
Current Consumption (typical) Fout < 24 MHz: 25 mA
24 MHz < Fout < 96 MHz: 65 mA max.
Fout > 96 MHz: 100 mA
Load 50 Ω into VDD or Thevenin Equivalent.
(terminating resistors required on all outputs)
Rise Time (TR)

0.6 nano sec. typical; 1.5 nano sec. max (20% ? 80%)

Fall Time (TF)

0.5 nano sec. typical; 1.5 nano sec. max (80% ? 20%)

Duty Cycle 50% ± 5% max. measured at VDD -1.3V
Phase Jitter (RMS)
(12 KHz to 20 MHz)
2.6 ps typical; 4 ps max. for 155.520 MHz
2.5 ps typical; 4 ps max. for 622.080 MHz
Phase Noise (RMS) typical 19.440 MHz 77.760 MHz 106.250 MHz 155.520 MHz 622.080 MHz
2.1 ps 3.5 ps 4.1 ps 4.3 ps 6.0 ps
Phase Noise (Peak-to-Peak) 17 ps 30 ps 28 ps 27 ps 40 ps
Phase Noise

(offset from carrier)
10 Hz Offset -80 dBc/Hz -75 dBc/Hz -70 dBc/Hz -60 dBc/Hz -50 dBc/Hz
100 Hz Offset -108 dBc/Hz -100 dBc/Hz -98 dBc/Hz -90 dBc/Hz -77 dBc/Hz
1 KHz Offset -132 dBc/Hz -125 dBc/Hz -122 dBc/Hz -115 dBc/Hz -102 dBc/Hz
10 KHz Offset -142 dBc/Hz -132 dBc/Hz -123 dBc/Hz -125 dBc/Hz -115 dBc/Hz
100 KHz Offset -142 dBc/Hz -130 dBc/Hz -117 dBc/Hz -119 dBc/Hz -108 dBc/Hz
 
Start-up Time 10 m sec. max.
Aging ±2 ppm per year max.
Tristate Option on Pad No. 1 No Connection PECL and complimentary PECL outputs.
Disable Both outputs are disabled (high impedance) when pad No. 1 is taken below 0.3 Vcc referenced to ground. Oscillator is always ON.
Special request: Oscillator is off when disabled. Contact Mercury.
Enable At disabled mode, both outputs are enabled when pad No. 1 is taken above 0.7 Vcc referenced to ground.
Input Static Discharge Protection 2 KV max.
Absolute Maximum Rating (permanent damage may be created if operate beyond limits specified.
Supply Voltage VDD +4.6 V D.C. max.
Input Voltage Vi Vss-0.5 min.; VDD + 0.5V max.
Input Voltage Vo Vss-0.5 min.; VDD + 0.5V max.
Storage Temperature TS -55°C min.; +150°C max.
(1)Inclusive of 25°C tolerance, operating temperature range, ±10% input voltage variation, load change, aging, shock and vibration.